create: Checkpoint 2026-11-26 16:49:53 UTC [e7d4a896fd]
MemRelay-Operation: checkpoint-save:ckpt-edl-9008-usb-drop-20261127-0048 MemRelay-Resource: 8b625a0d-a12a-437f-943e-175b9fb60a01
This commit is contained in:
+21
@@ -0,0 +1,21 @@
|
||||
---
|
||||
title: Checkpoint 2026-11-26 16:49:53 UTC [e7d4a896fd]
|
||||
type: checkpoint
|
||||
permalink: main/projects/bc51a377-ed2d-4afc-a176-554fce220d45/checkpoint-2026-11-26-16-49-53-utc-e7d4a896fd
|
||||
stable_id: 8b625a0d-a12a-437f-943e-175b9fb60a01
|
||||
scope: project
|
||||
memory_type: checkpoint
|
||||
project_id: bc51a377-ed2d-4afc-a176-554fce220d45
|
||||
usage_profile_id: 0c9feb46-d06e-43cd-9ef0-c5813c84a998
|
||||
status: active
|
||||
revision: 1
|
||||
request_id: ckpt-edl-9008-usb-drop-20261127-0048
|
||||
created_at: '2026-11-26T16:49:53.048494+00:00'
|
||||
updated_at: '2026-11-26T16:49:53.048494+00:00'
|
||||
tags:
|
||||
- edl
|
||||
- '9008'
|
||||
- handoff
|
||||
---
|
||||
|
||||
交接:原厂 Android 刷机尚未写入 eMMC。用户把 ImmortalWrt 板进入 9008,确认为 Qualcomm HS-USB QDLoader 9008 (COM5),InstanceId USB\VID_05C6&PID_9008\8&37F963D5&0&2,位置 Port_#0002.Hub_#0009。adb 为空。bkerler edl 用 --serial --portname=COM5 能打开端口并报 Mode detected: sahara,但高通 COM 驱动交不出可用握手,工具本身提示要换 Zadig 的 libusb/WinUSB。串口读超时被设成 1500 秒,进程会卡死,已杀掉。随后对该 PnP 节点做了 Disable/Enable,棒子掉成「未知 USB 设备(设备描述符请求失败)」USB\VID_0000&PID_0002\8&37F963D5&0&2,问题码 43。对 Realtek 集线器 USB\VID_0BDA&PID_5412 的 2 号口做了 IOCTL_USB_HUB_CYCLE_PORT(ok,StatusReturned=0),仍是描述符失败,9008 和 adb 都没回来。同一集线器 1 号口是键鼠 VID_260D&PID_0037,不要重启整个集线器。eMMC 没写过。刷机目录 Temp/ufi003-stock-flash/UFI003_MB_V02 里的 modemst1/2 仍是这块板的备份覆盖,不要重新解压覆盖。没有 patch0.xml,rawprogram0.xml 自带 gpt_main0.bin 和 gpt_backup0.bin。下一步:用户拔掉重插并按住复位再进 9008;先把 05C6:9008 换成 WinUSB 再 printgpt,成功后才 qfil。不要再 Disable 这个 9008 节点。不要写别人的 IMEI,不要刷包里原来的 modemst/fsg。
|
||||